Chapter 4
Hardware Modules
4 - 4
Features
The SCM provides or supports the following features and functions:
Switch Fabric
Non-blocking architecture for 40-Gbps full duplex non-blocking
aggregate throughput
10-Gbps full duplex throughput for each service module slot
Switch control-plane and data-plane functions
9K jumbo frames
Chassis Management
RS232/Console serial interface for local switch management
10/100 Management Ethernet interface for local/remote switch
management
Mirror port for monitoring and troubleshooting user ports
Service definition and policy enforcement
MAC-address assignment for modules
Real-time clock synchronization for modules
Gathering and monitoring of module health status and statistics through
LEDs and software
Module insertion/removal in a slot
Environmental Control and Management
The SCM also manages or monitors the following functions:
Temperature changes in the chassis and for each module
Module resets (for example, if a module’s temperature gets too high) or
power-down operation
Power draw for each module
Fan tray control interface
Dual-Channel SCM
The SCM’s dual-channel bus architecture enables it to communicate over
two separate buses to the system disk drives. This configuration provides an
additional level of redundancy by providing a second SCSI bus and permits
each SCSI drive to be connected to the SCM in slot 1. For more information
about the SCM and its bus interconnections, see Disk Drives
, on page 3-4.